Categories | HVAC Heating Ventilating Air Conditioning Manuals, Mitsubishi HVAC Manuals |
---|---|
Tags | Mitsubishi Mr Slim PLA, Mitsubishi RP BA IM RG79D251K01 |
Download File |
|
Language | English |
Product Brand | Heating, Ventilating and Air Conditioning Manual, Mitsubishi Electric US, Inc. Americas Corporate Office Phone: 714-220-2500; Application support or for technical information regarding applications for Mr. Slim, Toll-free: 1-800-433-4822 |
Document File Type | |
Publisher | mehvac.com |
Wikipedia's Page | Mitsubishi Electric |
Copyright | Attribution Non-commercial |
Air-Conditioners PLA-RP·BA INSTALLATION MANUAL FOR INSTALLER For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit. English Contents 1. 2. 3. 4. 5. Safety precautions .2 Installation location 3 Installing the indoor unit 3 Installing the refrigerant piping 5 Drainage piping work .6 6. 7. 8. 9. 10. Electrical work .7 Test run 14 System control 17 Installing the grille 17 Easy maintenance function .19 1.
Safety precautions Before installing the unit, make sure you read all the “Safety precautions “. Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system. Warning: Describes precautions that must be observed to prevent danger of injury or death to the user. Caution: Describes precautions that must be observed to prevent damage to the unit. Warning: · Ask a dealer or an authorized technician to install the unit. · For installation work, follow the instructions in the Installation Manual and use tools and pipe components specifically made for use with refrigerant specified in the outdoor unit installation manual. · The unit must be installed according to the instructions in order to minimize the risk of damage from earthquakes, typhoons, or strong winds. An incorrectly installed unit may fall down and cause damage or injuries. · The unit must be securely installed on a structure that can sustain its weight. · If the air conditioner is installed in a small room, measures must be taken to prevent the refrigerant concentration in the room from exceeding the safety limit in the event of refrigerant leakage. Should the refrigerant leak and cause the concentration limit to be exceeded, hazards due to lack of oxygen in the room may result. After installation work has been completed, explain the “Safety Precautions, ” use, and maintenance of the unit to the customer according to the information in the Operation Manual and perform the test run to ensure normal operation. Both the Installation Manual and Operation Manual must be given to the user for keeping. These manuals must be passed on to subsequent users. :Indicates a part which must be grounded. Warning: Carefully read the labels affixed to the main unit. · Ventilate the room if refrigerant leaks during operation. If refrigerant comes into contact with a flame, poisonous gases will be released. · All electric work must be performed by a qualified technician according to local regulations and the instructions given in this manual. · Use only specified cables for wiring. · The terminal block cover panel of the unit must be firmly attached. · Use only accessories authorized by Mitsubishi Electric and ask a dealer or an authorized technician to install them. · The user should never attempt to repair the unit or transfer it to another location. · After installation has been completed, check for refrigerant leaks. If refrigerant leaks into the room and comes into contact with the flame of a heater or portable cooking range, poisonous gases will be released. 1.1. Before installation (Environment) Caution: · Do not use the unit in an unusual environment. If the air conditioner is installed in areas exposed to steam, volatile oil (including machine oil), or sulfuric gas, areas exposed to high salt content such as the seaside, the performance can be significantly reduced and the internal parts can be damaged. · Do not install the unit where combustible gases may leak, be produced, flow, or accumulate. If combustible gas accumulates around the unit, fire or explosion may result. · Do not keep food, plants, caged pets, artwork, or precision instruments in the direct airflow of the indoor unit or too close to the unit, as these items can be damaged by temperature changes or dripping water. · When the room humidity exceeds 80% or when the drainpipe is clogged, water may drip from the indoor unit. Do not install the indoor unit where such dripping can cause damage. · When installing the unit in a hospital or communications office, be prepared for noise and electronic interference. Inverters, home appliances, highfrequency medical equipment, and radio communications equipment can cause the air conditioner to malfunction or breakdown. The air conditioner may also affect medical equipment, disturbing medical care, and communications equipment, harming the screen display quality. 1.2. Before installation or relocation Caution: · Be extremely careful when transporting the units. Two or more persons are needed to handle the unit, as it weighs 20 kg or more. Do not grasp the packaging bands. Wear protective gloves as you can injure your hands on the fins or other parts. · Be sure to safely dispose of the packaging materials. Packaging materials, such as nails and other metal or wooden parts may cause stabs or other injuries.