Carrier 58DL 9SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 54 pages
LanguageEnglish
Product BrandSupport Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

58DLA/DLX Single Stage Deluxe Induced Combustion 4 Way Multipoise Furnace Installation, Start up, Operating and Service and Maintenance Instructions Series 130/D SAFETY CONSIDERATIONS 2 INTRODUCTION 3 CODES AND STANDARDS 4 Safety 4 General Installation . 5 Combustion and Ventilation Air . 5 Duct Systems . 5 Acoustical Lining and Fibrous Glass Duct . 5 Gas Piping and Gas Pipe Pressure Testing . 5 Electrical Connections 5 Venting .

5 ELECTROSTATIC DISCHARGE PRECAUTIONS PROCEDURE . 5 LOCATION . 6 INSTALLATION 11 Upflow Installation 11 Downflow Installation . 11 Horizontal Installation . 13 Filter Arrangement 14 Air Ducts . 14 Gas Piping 17 115- Wiring 23 -V START-UP, ADJUSTMENT, AND SAFETY CHECK . 37 General . 37 Start- Procedures . 37 -up Adjustments . 37 Checklist 41 SERVICE AND MAINTENANCE PROCEDURES . 44 Introduction . 44 NOTE: Read the entire instruction manual before starting the installation. Portions of the text and tables are reprinted from NFPA 54/ANSI Z223.1-2006E, with permission of National Fire Protection Association, Quincy, MA 02269 and American Gas Association, Washington DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI on the referenced subject, which is represented only by the standard in its entirety. REGISTERED Care and Maintenance . 47 Sequence of Operation . 50 Wiring Diagrams . 52 Troubleshooting 52 ama ISO 9001:2000 CERTIFIED SAFETY CONSIDERATIONS ! WARNING FIRE, EXPLOSION, ELECTRICAL SHOCK, AND CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in dangerous operation, serious injury, death, or property damage. Improper installation, adjustment, alteration, service, maintenance, or use could cause carbon monoxide poisoning, explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified service agency, local gas supplier, or your distributor or branch for information or assistance. The qualified service agency must use only factory-authorized and listed kits or accessories when modifying this product. ! CAUTION FURNACE RELIABILITY HAZARD Improper installation or misapplication of furnace may require excessive servicing or cause premature component failure. Application of this furnace should be indoors with special attention given to vent sizing and material, gas input rate, air temperature rise, unit leveling, and unit sizing. ! CUT HAZARD CAUTION Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing furnaces. Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions include in literature and attached to the unit. Consult local building codes, the current editions of the National Fuel Gas Code (NFGC) NFPA 54/ANSI Z223.1 and the National Electrical Code (NEC) NFPA 70. In Canada, refer to the current editions of the National Standards of Canada CAN/CSA-B149.1 and .2 Natural Gas and Propane Installation Codes, and Canadian Electrical Code CSA C22.1 Recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.