Carrier 58CMR 1SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 12 pages
LanguageEnglish
Product BrandSupport Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

58CMR Multipoise Oil Furnace Visit www.carrier.com Installation, Start-Up, and Operating Instructions For Input Capacities of 70,000–154,000; Series 100 NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS SAFETY CONDSIDERATIONS 1 INTRODUCTION 2 LOCATION 2 General 2 Location Relative to Cooling Equipment 3 INSTALLATION .3 Air for Combustion and Ventilation 3 General 3 Unconfined Space .4 Confined Space .4 START-UP, ADJUSTMENT, AND SAFETY CHECKOUT 7 Operational Checkout .7 Combustion Check 7 Fan Adjustment Check .10 Limit Control Check .10 For Year-Round Air Conditioning .10 Heating 10 Cooling 10 Constant Blower Switch .10 MAINTENANCE .10 General 11 Oil Burner .11 Heat Exchanger and Flue Pipe .11 Blower Removal .11 SAFETY CONDSIDERATIONS FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

DO NOT ATTEMPT TO START THE BURNER WHEN EXCESS OIL HAS ACCUMULATED, WHEN THE FURNACE IS FULL OF VAPOR, OR WHEN THE COMBUSTION CHAMBER IS VERY HOT. A97247 Fig. 1–58CMR Multipoise Oil Furnace These instructions are intended to be used by qualified personnel who have been trained in installing this type of furnace. Installation of this furnace by an unqualified person may lead to equipment damage and/or a hazardous condition which may lead to bodily harm. All local and national code requirements governing installation of oil burning equipment, wiring, and flue connections must be followed. Some of the codes (issued by the Canadian Standards Association, the National Fire Protection Agency, and/or the American National Standards Institute) that may be applicable are: ANSI/NFPA 31: INSTALLATION OF OIL BURNING EQUIPMENT ANSI/NFPA 211: CHIMNEYS, FIREPLACES, VENTS, AND SOLID FUEL BURNING APPLIANCES For use with grade 1 or 2 fuel oil. Do not use gasoline, crankcase oil, or any oil containing gasoline! Failure to follow this warning could lead to sooting, fire, explosion, and/or severe bodily harm. ANSI/NFPA 90B: WARM AIR HEATING AND AIR CONDITIONING SYSTEMS ANSI/NFPA 70: NATIONAL ELECTRIC CODE CSA B139: INSTALLATION CODE FOR OIL BURNING EQUIPMENT CAS C22.1: CANADIAN ELECTRICAL CODE Only the latest issues of these codes should be used, and are available from either: The National Fire Protection Agency, Batterymarch Park, Quincy, MA 02269, or The Canadian Standards Association, 178 Rexdale Blvd., Rexdale, Ontario M9W1R3 Never burn garbage or paper in the heating system and never leave rags, paper, or any flammable items around the unit. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-80013 Printed in U.S.A.

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website