Carrier 58DF 2SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 2 pages
LanguageEnglish
Product BrandSupport Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Inducer Housing Relief Box Replacement Kit Cancels: New IIK 373L-35-5 12-15-91 Installation Instructions NOTE: Read the entire instruction before starting the installation. INTRODUCTION This instruction covers the installation of Inducer Housing and Relief Box Kit Part No. 310348-753 or -754 in a non-condensing, induced-combustion furnaces. SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components.

Heating, Ventilating and Air Conditioning User Manual Free Download. HAVC Operator’s Manual. Gas Furnace and AC Free Instruction Manual Download PDF.

Only trained personnel should install or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils, or cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, and on tags and labels attached to the unit. Follow all safety codes. Wear safety glasses and work gloves. Have a fire extinguisher available. DESCRIPTION AND USAGE The inducer housing and relief box replacement kit can be utilized to restore a unit when the inducer housing or relief box has failed. The Gasket Kit contains the following items: Inducer housing assembly Safeguard tube Screw Gasket Installation Instructions 1. Turn OFF gas and electrical supply to furnace. 2. Remove blower and control access doors. 3. Disconnect and remove vent pipe. 4. Unplug inducer motor. 5. Disconnect wires from pressure switch and draft safeguard switch. 6. Remove screws securing relief box to top plate (upflow) or to blower shelf (downflow/horizontal). 7. Disconnect pressure switch tube from collector box fitting. (1) (2) (2) (2) (1) Part No. 310348-753 & -754 8. Remove screws securing inducer assembly (motor, wheel, and mount) from inducer housing. Remove inducer assembly from furnace. 9. Remove screws inside inducer housing and remove assembly from furnace. 10. Remove following items from old inducer assembly for use on new assembly: a. Pressure switch b. Flue tab, (located in the inducer housing outlet) if applicable or flue choke plate, (located in the inducer housing inlet) if applicable c. Draft safeguard switch Step 2–Installation of New Inducer Housing and Relief Box Assembly 1.

Wikipedia’s page for Carrier

Carrier Company Web Site: www.corp.carrier.com

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website