Carrier 58MCA 1SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 36 pages
LanguageEnglish
Product BrandSupport Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Installation, Start-Up, and Operating Instructions For Sizes 040–120 Series 121 ® ama CANADIAN GAS ASSOCIATION A PP R O VED R As an ENERGY STAR Partner, Carrier Corporation has determined that this product meets the ENERGY STAR guidelines for energy efficiency. A93040 AIRFLOW NOTE: Read the entire instruction manual before starting the installation.

This symbol indicates a change since the last issue. Index Page UPFLOW DIMENSIONAL DRAWING 2 SAFETY CONSIDERATIONS .3 Clearances to Combustibles 3 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS 3-4 INTRODUCTION 4 APPLICATIONS 4-11 General 4 Upflow Applications 4-6 Downflow Applications .7-8 Horizontal Left (Supply-Air Discharge) Applications .8-9 Horizontal Right (Supply-Air Discharge) Applications .9-11 LOCATION 11-12 General .11-12 Furnace Location Relative to Cooling Equipment 12 Hazardous Locations .12 INSTALLATION 12-16 Leveling Legs (If Desired) 12-13 Installation On a Concrete Slab .13 Installation On a Combustible Floor (Downflow Applications) 13-14 Installation In Horizontal Applications 14 Filter Arrangement 15 Bottom Closure Panel .15 Gas Piping 15-16 ELECTRICAL CONNECTIONS .16-19 115-v Wiring 16-17 24-v Wiring 17-19 Accessories 19 DIRECT VENTING .20-27 Removal of Existing Furnaces from Common Vent Systems .20 Combustion-Air and Vent Piping .20-25 Concentric Vent and Combustion-Air Termination Kit Installation 25-27 Multiventing and Vent Termination .27 HORIZONTAL LEFT DOWNFLOW AIRFLOW HORIZONTAL RIGHT AIRFLOW AIRFLOW Fig. 1–Multipoise Orientations A93041 CONDENSATE DRAIN 27-29 General 27 Application .27-29 Condensate Drain Protection 29 SEQUENCE OF OPERATION 29-31 Heating Mode 29-30 Cooling Mode .30 Continuous Blower Mode .30 Heat Pump Mode 30 Component Test .30-31 START-UP PROCEDURES 31-35 General 31 Prime Condensate Trap With Water 31 Purge Gas Lines 32 Adjustments .32-35 Set Gas Input Rate 32-34 Set Temperature Rise 34 Blower Off Delay (Heat Mode) .35 Set Thermostat Heat Anticipator 35 CHECK SAFETY CONTROLS 35 Check Primary Limit Control .35 Check Pressure Switch .35 CHECKLIST .35-36 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 565-907 Printed in U.S.A. Form 58MCA-1SI Pg 1 7-95 Replaces: 58MXA-3SI Tab 6a 8a

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website