Categories | Carrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals |
---|---|
Tags | Carrier 58MTA |
Download File |
|
Language | English |
Product Brand | Support Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC |
Document File Type | |
Publisher | corp.carrier.com |
Wikipedia's Page | Carrier Corporation |
Copyright | Attribution Non-commercial |
58MTA Deluxe 4-Way Multipoise Variable-Capacity Direct-Vent Condensing Gas Furnace Visit www.carrier.com Service and Maintenance Instructions For Sizes 060-120, Series 100 NOTE: Read the entire instruction manual before starting the installation. EFFICIENCY RATING CERTIFIED Ca rr ier Cor pora ti on CERTIFIED SO 900 E R E D F8 3 1 #A28 REGISTERED QUALITY SYSTEM A93040 TABLE OF CONTENTS SAFETY CONSIDERATIONS .1 INTRODUCTION 2 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS 2 CARE AND MAINTENANCE .2 Cleaning and/or Replacing Air Filter .3 Blower Motor and Wheel Maintenance .3 Cleaning Burners 5 Cleaning Heat Exchangers 5 Flushing Collector Box and Drainage System 7 Servicing Hot Surface Ignitor 8 Electrical Controls and Wiring .8 Checking Heat Tape Operation (If Applicable) 9 Winterizing 9 WIRING DIAGRAM .9 TROUBLESHOOTING .9 Status Codes 9 Component Test 10 SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components.
Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to or shipped with the unit and other safety precautions that may apply. Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA 54-1999/ANSI Z223.1-1999 and the Installation Standards, Warm Air Heating and Air Conditioning Systems (NFPA 90B) ·· ·· U L T R A H I G H G A S E F F I C I E N C Y F U R N A N C E IR ® Fig. 1–Multipoise Furnace in Upflow Orientation ANSI/NFPA 90B. In Canada, refer to the CAN/CGA-B/49.1- and .2-M00 National Standard of Canada, Natural Gas and Propane Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-80001 Printed in U.S.A. Form 58MTA-1SM Pg 1 3-01 Replaces: New Tab 6a 8a REG I ST ® ·· M I A92496 Installation Codes (NSCNGPIC). Wear safety glasses and work gloves. Have a fire extinguisher available during start-up and adjustment procedures and service calls. This is the safety-alert symbol. When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. AIRFLOW UPFLOW HORIZONTAL LEFT DOWNFLOW AIRFLOW HORIZONTAL RIGHT AIRFLOW AIRFLOW The ability to properly perform maintenance on this equipment requires certain knowledge, mechanical skills, tools, and equipment.