Carrier 58MVP 9SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 48 pages
LanguageEnglish
Product BrandSupport Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

58MVP 4-Way Multipoise Direct-Vent Variable-Capacity Condensing Gas Furnace Visit www.carrier.com Installation, Start-Up, and Operating Instructions For Sizes 040–120, Series 130 and 140 NOTE: Read the entire instruction manual before starting the installation. ® ama CANADIAN GAS ASSOCIATION A PP R O VED R A93040 This symbol indicates a change since the last issue. Index Page DIMENSIONAL DRAWING 2 SAFETY CONSIDERATIONS .3 Clearances to Combustibles 3 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS 3-4 INTRODUCTION 4 APPLICATIONS 4-11 General 4 Upflow Applications 4-7 Downflow Applications .7-8 Horizontal Left (Supply-Air Discharge) Applications .8-9 Horizontal Right (Supply-Air Discharge) Applications .9-11 LOCATION 11-13 General .11-12 Low-Fire Only Installation 12-13 Furnace Location Relative to Cooling Equipment 13 Hazardous Locations .13 INSTALLATION 13-17 Leveling Legs (If Desired) .13 Installation In Upflow or Downflow Applications 13-15 Installation In Horizontal Applications 15 Air Ducts .15 Filter Arrangement 16 Bottom Closure Panel .16 Gas Piping .17 ELECTRICAL CONNECTIONS .17-21 115-v Wiring 17-18 24-v Wiring 18-20 Accessories 20-21 DIRECT VENTING .21-29 Removal of Existing Furnaces from Common Vent Systems .21 Combustion-Air and Vent Piping .21-26 Concentric Vent and Combustion-Air Termination Kit Installation 26-29 Multiventing and Vent Terminations .29 CONDENSATE DRAIN 30-31 General 30 Application 30 Condensate Drain Protection .30-32 SEQUENCE OF OPERATION 32-36 Self-Test Mode 32 As an ENERGY STAR® Partner, Carrier Corporation has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.

REGISTERED QUALITY SYSTEM AIRFLOW UPFLOW HORIZONTAL LEFT DOWNFLOW AIRFLOW HORIZONTAL RIGHT AIRFLOW AIRFLOW Fig. 1–Multipoise Orientations A93041 Heating Mode 32-33 Heating Mode–Two Stage 33 Emergency Heat Mode .33 Cooling Mode 33-34 Heat Pump Mode 34 Continuous Fan Mode .34-35 Component Test 35 Bypass Humidifier Mode 35 Dehumidification Mode .35-36 Zone Mode 36 START-UP PROCEDURES 36-44 General 36 Select Setup Switch Positions .36-37 Prime Condensate Trap With Water 37 Purge Gas Lines 37 Adjustments .37-43 Set Gas Input Rate 37-43 Set Temperature Rise 43 Set Thermostat Heat Anticipator 44 CHECK SAFETY CONTROLS 44 Check Primary Limit Control .44 Check Pressure Switch .44 CHECKLIST .44-45 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-747 Printed in U.S.A. Form 58MVP-9SI Pg 1 5-99 Replaces: 58MVP-8SI Tab 6a 8a 26 15/16 ” 26 15/16 ” AIRFLOW 26 1/4 ” 22 5/16 ” 19 ” OUTLET 2-IN.

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website