Carrier 58MXA 3SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 36 pages
LanguageEnglish
Product BrandSupport Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

58MCA, 58MXA Multipoise Gas-Fired Condensing Furnace Installation, Start-Up, and Operating Instructions For Sizes 040–120 Series 111 CANADIAN GAS ASSOCIATION ® ama AIRFLOW A PP R O VED R A93040 UPFLOW NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. Index Page HORIZONTAL LEFT DOWNFLOW AIRFLOW AIRFLOW HORIZONTAL RIGHT DIMENSIONAL DRAWING 2 SAFETY CONSIDERATIONS .3 Clearances to Combustibles 3 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE 3-4 INTRODUCTION 4 APPLICATIONS 4-11 General 4 Upflow Applications 4-6 Downflow Applications .7-8 Horizontal Left (Supply-Air Discharge) Applications .8-9 Horizontal Right (Supply-Air Discharge) Applications .9-11 LOCATION 11-12 General .11-12 Furnace Location Relative to Cooling Equipment 12 Hazardous Locations .12 INSTALLATION 12-16 Leveling Legs (If Desired) 12-13 Installation On a Concrete Slab .13 Installation On a Combustible Floor (Downflow Applications) 13-14 Installation In Horizontal Applications 14 Filter Arrangement 15 Bottom Closure Panel .15 Gas Piping 15-16 ELECTRICAL CONNECTIONS .16-18 115-v Wiring 16-18 24-v Wiring .18 Accessories 18 DIRECT VENTING .18-27 Removal of Existing Furnaces from Common Vent Systems .18 Combustion-Air and Vent Piping .18-25 Concentric Vent and Combustion-Air Termination Kit Installation 25-27 AIRFLOW Fig.

1–Multipoise Orientations A93041 Multiventing and Vent Termination .27 CONDENSATE DRAIN 27-29 General .27-29 Application 29 Condensate Drain Protection 29 SEQUENCE OF OPERATION 30-31 Heating Mode 30 Cooling Mode .30 Continuous Blower Mode .30 Heat Pump Mode 30 Component Test .30-31 START-UP PROCEDURES 31-35 General 31 Prime Condensate Trap With Water 31 Purge Gas Lines 31 Adjustments .31-35 Set Gas Input Rate 31-34 Set Temperature Rise 34-35 Adjust Blower Off Delay (Heat Mode) .35 Set Thermostat Heat Anticipator 35 CHECK SAFETY CONTROLS 35 Check Primary Limit Control .35 Check Pressure Switch .35 CHECKLIST .35-36 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 565-830 Printed in U.S.A. Form 58MXA-3SI Pg 1 12-94 Replaces: 58MXA-2SI Tab 6a 8a 26 15/16 ” 26 15/16 ” AIRFLOW 26 1/4 ” 22 5/16 ” 13/16 ” 9/16 ” 28 1/2 ” 26 1/4 ” A 13/16 ” 24 1/2 ” D TYP OUTLET 2-IN. COMBUSTIONAIR CONN /2-IN.

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website