Categories | Carrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals |
---|---|
Tags | Carrier 58RA |
Download File |
|
Language | English |
Product Brand | Support Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC |
Document File Type | |
Publisher | corp.carrier.com |
Wikipedia's Page | Carrier Corporation |
Copyright | Attribution Non-commercial |
58RAV Downflow/Horizontal Induced-Combustion Furnaces Visit www.carrier.com Installation, Start-Up, and Operating Instructions Sizes 050-135, Series 170 and 180 NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. Index Page SAFETY CONSIDERATIONS .1 Dimensional Drawing .2 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE .2 INTRODUCTION .3-4 Clearances From Combustible Materials .3 LOCATION 4 General 4 Location Relative to Cooling Equipment 4 Hazardous Locations .4 AIR FOR COMBUSTION AND VENTILATION .4-5 Unconfined Space 4-5 Confined Space .5 AIR DUCTS .5 General Requirements .5 Ductwork Acoustical Treatment .6 Supply-Air Connections 6 Return-Air Connections 6 DOWNFLOW INSTALLATION 7 HORIZONTAL ATTIC INSTALLATION .7 Construct a Working Platform .7 Install Furnace .7-9 HORIZONTAL CRAWLSPACE INSTALLATION 9 FILTER ARRANGEMENT .9 GAS PIPING 9 ELECTRICAL CONNECTIONS .10-11 115-v Wiring .10 24-v Wiring .11 Accessories 11 VENTING 11 START-UP, ADJUSTMENT, AND SAFETY CHECK 13 General 13 Sequence Of Operation .13 Heating Mode 13 Cooling Mode .13 Continuous Blower Mode .13 Heat Pump Mode 14 Start-up Procedures .15 Adjustments .15 Set Gas Input Rate 15-18 Set Temperature Rise 18-19 Set Thermostat Heat Anticipator 19-20 Check Safety Controls 20 Checklist 20 SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components.
Only trained and qualified personnel should install, repair, or service heating equipment. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-767 Printed in U.S.A. Form 58RA-16SI Pg 1 10-00 Replaces: 58RA-14SI Tab 6a 8a ama CERTIFIED REGISTERED QUALITY SYSTEM Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to or shipped with the unit and other safety precautions that may apply. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA 54-1999/ANSI Z223.1-1999 and the Installation Standards, Warm Air Heating and Air Conditioning Systems (NFPA 90B) ANSI/NFPA 90B. In Canada, refer to the CAN/CGA-B149.1- and .2-M95 National Standard of Canada, Natural Gas and Propane Installation Codes (NSCNGPIC). Wear safety glasses and work gloves. Have fire extinguisher available during start-up and adjustment procedures and service calls. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.