Carrier 58WAV 3SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals, HVAC Heating Ventilating Air Conditioning Manuals
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 14 pages
LanguageEnglish
Product BrandSupport Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays, Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Weathermaker 8000TM 58WAV Induced-Combustion Furnaces Installation, Start-Up, and Operating Instructions Sizes 045-155, Series 121 NOTE: Read the entire instruction manual before starting the installation. Index Page SAFETY CONSIDERATIONS .1 Clearances From Combustible Materials .1 INTRODUCTION .1-2 Dimensional Drawing .2 LOCATION 3 General 3 Location Relative to Cooling Equipment 3 Hazardous Locations .3 AIR FOR COMBUSTION AND VENTILATION .3-4 Unconfined Space .3 Confined Space 3-4 FILTER ARRANGEMENT .4-5 LEVELING LEGS (IF REQUIRED) 5 GAS PIPING .5-6 ELECTRICAL CONNECTIONS .6-8 115-v Wiring 6-7 24-v Wiring .7 Accessories 7-8 VENTING 8 START-UP, ADJUSTMENT, AND SAFETY CHECK .8-14 General .8-10 Sequence Of Operation .10 Heating Mode 10 Cooling Mode .10 Continuous Blower Mode .10 Heat Pump Mode 10 Start-Up Procedures .10-11 Adjustments .11-13 Set Gas Input Rate 11-13 Set Temperature Rise 13 Set Thermostat Heat Anticipator 13 Check Safety Controls 13-14 Checklist .14 SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components.

Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to or shipped with the unit and other safety precautions that may apply. Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA No. 54-1992/ANSI Z223.1-1992. In Canada, refer to the current edition of the National Standard of Canada CAN/CGA-B149.1and .2-M91 Natural Gas and Propane Installation Codes (NSC- ® ama CANADIAN GAS ASSOCIATION A PP R O VED R NGPIC). Wear safety glasses and work gloves. Have fire extinguisher available during start-up and adjustment procedures and service calls. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury. Understand the signal word DANGER, WARNING, or CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard that could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions that will result in enhanced installation, reliability, or operation. These instructions cover minimum requirements and conform to existing national standards and safety codes. In some instances, these instructions exceed certain local codes and ordinances, especially those that may not have kept up with changing residential construction practices. We require these instructions as a minimum for a safe installation. Table 1–Minimum Clearances From Combustible Materials (In.) 045 AND 070 091-155 1 0 0 0 Back 0 0 Plenum Top 1 1 Vent Single-Wall Vent 6 6 Type B-1 Double-Wall Vent 1 1 Front Single-Wall Vent 6 6 Type B-1 Double-Wall Vent 3 3 Service 30 30 Single-Wall Vent Type B-1 Double-Wall Vent NOTES: 1. Provide 30-in. front clearance for servicing. An open door in front of the unit can meet this requirement. 2. A minimum clearance of 3 in. must be provided in front of the unit for combustion air and proper operation. UNIT SIZE Sides INTRODUCTION The Model 58WAV, Series 121 Furnace is available in sizes 45,000 through 155,000 Btuh input capacities. The design of the upflow gas-fired furnace is A.G.A./C.G.A. certified for natural and propane gas and for installation on combustible flooring, in alcoves, attics, basements, closets, or utility rooms. The design of this furnace line is not A.G.A./C.G.A. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-862 Printed in U.S.A. Form 58WAV-3SI Pg 1 4-94 Replaces: 58WAV-2SI Tab 6a 8a A88367 Fig. 1

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website