Mitsubishi Mr Slim BG79U156H02 RLA RP AA Ceiling Cassette Air Conditioner Installation Instructions

Product Specification
CategoriesHVAC Heating Ventilating Air Conditioning Manuals, Mitsubishi HVAC Manuals
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 28 pages
Language中文 Zhōngwén, English
Product BrandHeating, Ventilating and Air Conditioning Manual, Mitsubishi Electric US, Inc. Americas Corporate Office Phone: 714-220-2500; Application support or for technical information regarding applications for Mr. Slim, Toll-free: 1-800-433-4822
Document File TypePDF
Publishermehvac.com
Wikipedia's PageMitsubishi Electric
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Air-Conditioners PLA-RP·AA INSTALLATION MANUAL FOR INSTALLER For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. English Contents 1. Safety precautions . Installation location Installing the indoor unit . Installing the pipes . Refrigerant piping work Drainage piping work . 6 Electrical work 6 Test run 9 System controll .

11 Installing the grille . 11 1. Safety precautions s Before installing the unit, make sure you read all the “Safety precautions “. s Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system. Warning: Describes precautions that must be observed to prevent danger of injury or death to the user. Caution: Describes precautions that must be observed to prevent damage to the unit. After installation work has been completed, explain the “Safety Precautions, ” use, and maintenance of the unit to the customer according to the information in the Operation Manual and perform the test run to ensure normal operation. Both the Installation Manual and Operation Manual must be given to the user for keeping. These manuals must be passed on to subsequent users. Warning: · Ask a dealer or an authorized technician to install the unit. · For installation work, follow the instructions in the Installation Manual and use tools and pipe components specifically made for use with refrigerant specified in the outdoor unit installation manual. · The unit must be installed according to the instructions in order to minimize the risk of damage from earthquakes, typhoons, or strong winds. An incorrectly installed unit may fall down and cause damage or injuries. · The unit must be securely installed on a structure that can sustain its weight. · If the air conditioner is installed in a small room, measures must be taken to prevent the refrigerant concentration in the room from exceeding the safety limit in the event of refrigerant leakage. Should the refrigerant leak and cause the concentration limit to be exceeded, hazards due to lack of oxygen in the room may result. : Indicates an action that must be avoided. : Indicates that important instructions must be followed. : Indicates a part which must be grounded. : Indicates that caution should be taken with rotating parts. : Indicates that the main switch must be turned off before servicing. : Beware of electric shock. : Beware of hot surface. ELV : At servicing, please shut down the power supply for both the Indoor and Outdoor Unit. Warning: Carefully read the labels affixed to the main unit. · Ventilate the room if refrigerant leaks during operation. If refrigerant comes into contact with a flame, poisonous gases will be released. · All electric work must be performed by a qualified technician according to local regulations and the instructions given in this manual. · Use only specified cables for wiring. · The terminal block cover panel of the unit must be firmly attached. · Use only accessories authorized by Mitsubishi Electric and ask a dealer or an authorized technician to install them. · The user should never attempt to repair the unit or transfer it to another location. · After installation has been completed, check for refrigerant leaks. If refrigerant leaks into the room and comes into contact with the flame of a heater or portable cooking range, poisonous gases will be released. 1.1. Before installation (Euvironment) Caution: · Do not use the unit in an unusual environment. If the air conditioner is installed in areas exposed to steam, volatile oil (including machine oil), or sulfuric gas, areas exposed to high salt content such as the seaside, the performance can be significantly reduced and the internal parts can be damaged. · Do not install the unit where combustible gases may leak, be produced, flow, or accumulate. If combustible gas accumulates around the unit, fire or explosion may result. · Do not keep food, plants, caged pets, artwork, or precision instruments in the direct airflow of the indoor unit or too close to the unit, as these items can be damaged by temperature changes or dripping water. · When the room humidity exceeds 80% or when the drainpipe is clogged, water may drip from the indoor unit.

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website